Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Dental Press J Orthod ; 26(2): e211945, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34008740

RESUMO

OBJECTIVE: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. METHODS: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] and Orthometric® [G5]) underwent cross-sectional dimension measurements, tensile tests, SEM-EDS and differential scanning calorimetry (DSC) tests. Parametric tests (One-way ANOVA and Tukey post-test) were used, with a significance level of 5%, and Pearson's correlation coefficient test was performed between the Af and chemical elements of the wires. All sample tests and statistical analyses were double-blinded. RESULTS: All wires presented standard dimensions (0.017 x 0.025-in) and superelastic behavior, with mean plateau forces of: G1 = 36.49N; G2 = 27.34N; G3 = 19.24 N; G4 = 37.54 N; and G5 = 17.87N. The Af means were: G1 = 29.40°C, G2 = 29.13°C and G3 = 31.43°C, with p>0.05 relative to each other. G4 (32.77°C) and G5 (35.17°C) presented statistically significant differences between each other and among the other groups. All samples presented Ni, Ti, Cu and Al in different concentrations. CONCLUSIONS: The chemical concentration of the elements that compose the alloy significantly influenced the thermodynamic and mechanical properties.


Assuntos
Ligas Dentárias , Fios Ortodônticos , Estudos Transversais , Elasticidade , Teste de Materiais , Estresse Mecânico , Titânio
2.
Dental press j. orthod. (Impr.) ; 26(2): e211945, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1249705

RESUMO

ABSTRACT Objective: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. Methods: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] and Orthometric® [G5]) underwent cross-sectional dimension measurements, tensile tests, SEM-EDS and differential scanning calorimetry (DSC) tests. Parametric tests (One-way ANOVA and Tukey post-test) were used, with a significance level of 5%, and Pearson's correlation coefficient test was performed between the Af and chemical elements of the wires. All sample tests and statistical analyses were double-blinded. Results: All wires presented standard dimensions (0.017 x 0.025-in) and superelastic behavior, with mean plateau forces of: G1 = 36.49N; G2 = 27.34N; G3 = 19.24 N; G4 = 37.54 N; and G5 = 17.87N. The Af means were: G1 = 29.40°C, G2 = 29.13°C and G3 = 31.43°C, with p>0.05 relative to each other. G4 (32.77°C) and G5 (35.17°C) presented statistically significant differences between each other and among the other groups. All samples presented Ni, Ti, Cu and Al in different concentrations. Conclusions: The chemical concentration of the elements that compose the alloy significantly influenced the thermodynamic and mechanical properties.


RESUMO Objetivo: O presente artigo teve como objetivo verificar as propriedades termodinâmicas, mecânicas e químicas de fios CuNiTi 35°C comerciais. Métodos: Foram utilizados 40 arcos termodinâmicos pré-contornados de cobre-níquel-titânio de 0,017" x 0,025" e temperatura Af de 35°C. Oito fios de cinco fabricantes diferentes (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] e Orthometric® [G5]) foram submetidos a medições de suas secções transversais, testes de tração, MEV-EDS e calorimetria diferencial (DSC). Foram utilizados testes paramétricos (One-way ANOVA e pós-teste de Tukey), com nível de significância de 5%, e foi realizado o teste do coeficiente de correlação de Pearson entre a temperatura Af e os elementos químicos dos fios. Todos os testes das amostras e análises estatísticas foram duplo-cegos. Resultados: Todos os fios apresentavam dimensões padronizadas (0,017" x 0,025") e comportamento superelástico, com forças médias de platô de G1 = 36,49 N; G2 = 27,34 N; G3 = 19,24 N; G4 = 37,54 N; e G5 = 17,87 N. As médias de Af foram: G1 = 29,40°C, G2 = 29,13°C e G3 = 31,43°C, com p> 0,05 entre si. G4 (32,77°C) e G5 (35,17°C) apresentaram diferenças estatisticamente significativas entre si e entre os demais grupos. Todas as amostras apresentaram Ni, Ti, Cu e Al em diferentes concentrações. Conclusões: A concentração química dos elementos que compõem a liga influenciou significativamente as propriedades termodinâmicas e mecânicas.


Assuntos
Fios Ortodônticos , Ligas Dentárias , Estresse Mecânico , Titânio , Teste de Materiais , Estudos Transversais , Elasticidade
3.
J Clin Exp Dent ; 11(11): e1000-e1005, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31700573

RESUMO

BACKGROUND: Repairs in composite resin restorations are common procedures in clinical practice. Many surface treatment options have been proposed to improve the adhesion between the old and new composite. The objective of this study was to evaluate the microtensile bond strength of repairs performed on aged bulk fill and conventional composites after different adhesion protocols. MATERIAL AND METHODS: First, 84 specimens (8x8x4 mm3) of a microhybrid composite and a high-viscosity bulk fill composite were prepared and aged. Afterward, they received a mechanical surface treatment by means of abrasion with a diamond bur, followed by division into six groups according to the adhesion protocol employed: PSA - etching with 35% phosphoric acid + silane + etch-and-rinse adhesive; SA - silane + etch-and-rinse adhesive; PA - etching with 35% phosphoric acid + etch-and-rinse adhesive; A - etch-and-rinse adhesive; PU - 35% phosphoric acid + universal adhesive; and U - universal adhesive. The repairs were performed with a microhybrid composite. Repaired resin blocks were cut into sticks (8x1x1 mm3) and submitted to a microtensile test. Fractured specimens were evaluated to determine the failure pattern (adhesive or cohesive). Data were analyzed by two-way ANOVA. RESULTS: No statistically significant differences were found in bond strength values among different adhesion protocols and composite types. CONCLUSIONS: The repair bond strength of a bulk fill composite was similar to that found in a conventional composite, with no distinction among adhesion protocols. Key words:Dental restoration repair, composite resins, adhesiveness.

4.
Rev. odontol. UNESP (Online) ; 46(6): 330-335, Nov.-Dec. 2017. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-902685

RESUMO

Introdução: A rugosidade de superfície é uma limitação que interfere nos desempenhos mecânico e estético do cimento de ionômero de vidro (CIV), sendo necessária a utilização de procedimentos para acabamento e polimento adequados às propriedades desse material. Objetivo: Avaliar o efeito de diferentes sistemas de acabamento e polimento na rugosidade, dureza e superfície de restaurações realizadas com dois tipos de CIV. Material e método: Foram utilizados 100 corpos de prova (CP), divididos em 10 grupos, de acordo com o tipo de CIV (convencional e modificado por resina) e o sistema de acabamento e polimento empregado [C-tira de poliéster (controle); PD-ponta diamantada; DA-discos abrasivos; PE-ponta Enhance; BM-broca multilaminada]. Após sete dias em água destilada, os CP foram avaliados em Microscópio Eletrônico de Varredura (MEV) e submetidos aos testes de rugosidade de superfície e microdureza Vickers. A análise estatística foi realizada com ANOVA dois fatores e pós-Teste de Tukey. Resultado: A análise por MEV indicou superfície mais lisa no grupo BM em ambos os tipos de CIV. Quanto à rugosidade, observou-se diferença estatisticamente significante (p<0,05) entre grupos do CIV convencional, mas não houve diferença entre os tipos de CIV. Com relação à dureza, o CIV convencional apresentou melhores resultados que o modificado por resina. No fator materiais de acabamento e polimento, não se verificou diferença estatisticamente significativa, independentemente do tipo de CIV. Conclusão: os grupos BM apresentaram melhores resultados ao MEV; o tipo de CIV não influenciou os valores de rugosidade; o tipo de polimento não influenciou a dureza.


Introduction: The roughness of glass ionomer cement (GIC) is a limitation that interferes with its mechanical and aesthetic performance, and it is necessary to use appropriate finishing and polishing procedures in restorations produced with this material. Objective: To evaluate the effect of different finishing and polishing systems on roughness, hardness and surface of restorations performed with two types of GIC. Material and method: 100 specimens were made and divided into 10 groups, according to the type of GIC (conventional and resin modified GIC) and the finishing and polishing system used (C (Control) - Mylar strip; PD - diamond burs; DA - abrasive disks; PE - Enhance system; BM - carbide burs). After 7 days in distilled water, the specimens were evaluated by Scanning Electron Microscopy (SEM) and submitted to surface roughness and Vickers microhardness tests. Statistical analysis was performed by two-way ANOVA and Tukey post-test. Result: SEM analysis demonstrated a smoother surface in BM group in both types of GIC. Regarding roughness, a statistically significant difference (p <0.05) was observed between some groups of conventional GIC, but there was no difference between GIC types. Regarding hardness, conventional GIC showed better results than resin-modified GIC; Concerning to finishing and polishing materials factor, there was no statistically significant difference, regardless of the type of GIC. Conclusion: BM groups presented better results on SEM; The type of GIC did not influence the roughness values; The type of polishing did not influence the hardness.


Assuntos
Propriedades de Superfície , Microscopia Eletrônica de Varredura , Análise de Variância , Polimento Dentário , Cimentos de Ionômeros de Vidro , Testes de Dureza
5.
Dental press j. orthod. (Impr.) ; 22(6): 61-67, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891107

RESUMO

ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.


RESUMO Objetivo: avaliar as mudanças no sistema de forças das molas T pré-ativadas por curvatura, devido ao alívio de tensão estrutural. Métodos: noventa molas em forma de "T", medindo 6 mm x 10 mm, confeccionadas com fio de beta-titânio TMA® de 0,017" x 0,025" e pré-ativadas por curvatura gradual, foram distribuídas aleatoriamente em nove grupos, de acordo com o momento de avaliação. O Grupo 1 foi testado imediatamente após a pré-ativação da mola e liberação do estresse, por meio de simulação da ativação. Os outros oito grupos foram divididos conforme o intervalo de tempo testado: após 24, 48 e 72 horas; 1, 2, 4, 8 e 12 semanas. Usando um transdutor de momentos acoplado a um indicador digital para extensometria e adaptado a uma máquina universal de ensaios, as magnitudes da força horizontal, do momento e da proporção momento/força (M/F) foram registradas a cada 0,5 mm de desativação a partir da ativação inicial de 5 mm, utilizando-se uma distância interbraquetes de 23 mm. Resultados: as forças horizontais reduziram-se gradualmente nos grupos (p< 0,001) e o momento apresentou uma queda lenta e significativa ao longo do tempo (p< 0,001). Todos os grupos tiveram proporções M/F semelhantes (p= 0,532), não influenciadas pelo período de tempo. Conclusões: as molas pré-ativadas por curvatura gradual sofreram deformação progressiva ao longo do tempo, o que afetou o sistema de forças - especificamente o momento -, alterando as forças horizontais produzidas.


Assuntos
Fios Ortodônticos , Titânio/química , Desenho de Aparelho Ortodôntico , Fechamento de Espaço Ortodôntico/instrumentação , Ligas Dentárias/química , Análise do Estresse Dentário , Estresse Mecânico , Fatores de Tempo , Fenômenos Biomecânicos , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas
6.
Rev. odontol. UNESP (Online) ; 46(4): 244-248, July-Aug. 2017. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-902661

RESUMO

Introduction: One of the most common treatments of head and neck cancer patients is radiotherapy, a treatment method which uses ionizing radiation beam and destroys tumor cells, minimizing damage to neighbor cells. Purpose: To evaluate the bond strength of a conventional adhesive system in irradiated teeth. Method: 24 third human molars, 12 of which were randomly exposed to radiation and prepared from the removal of occlusal enamel, then exposed to a flat dentine surface. The adhesive system Stae was applied according to the manufacturer's instructions. Next, two 2 mm increments of resin were implemented. The samples were hemi sectioned specimens, originating shapped toothpick. To evaluate the bond strength, a micro tensile test was done with 500N load and speed of 0.5 mm/minute. Result: There was no statistically significant difference between the bond strength of teeth which were or were not exposed to radiation and which used a conventional adhesive system. Conclusion: Although the radiation doses applied may cause some alterations in microscopic range in dental tissues, it can be concluded that these alterations do not influence in the bond strength in dentin of irradiated teeth.


Introdução: Um dos tratamentos mais comuns dos pacientes portadores de câncer na região de cabeça e pescoço é a radioterapia, um método de tratamento que utiliza feixe de radiação ionizante e tem por finalidade destruir as células tumorais, minimizando danos às células vizinhas. Objetivo: Avaliar a resistência de união de um sistema adesivo convencional em dentes irradiados. Método: 24 terceiros molares, dos quais 12 foram aleatoriamente expostos à irradiação e preparados a partir da remoção do esmalte oclusal, expondo, dessa forma, uma superfície de dentina. O sistema adesivo Stae foi aplicado de acordo com as instruções do fabricante e em seguida acrescentou-se dois incrementos de resina de 2 mm. Os corpos de prova foram hemi-seccionados originando espécimes em forma de palito. Para avaliação da resistência de união, foi realizado o ensaio de microtração com carga de 500N e velocidade de 0,5mm/min. Resultado: Não houve diferença estatística significante entre a resistência de união de dentes que foram ou não expostos à irradiação e que utilizaram um sistema adesivo convencional. Conclusão: Embora as doses de radiação aplicadas causem algum tipo de alteração em escala microscópica nos tecidos dentários, essas alterações não interferiram na resistência de união.


Assuntos
Adesividade , Adesivos Dentinários , Resinas Compostas , Resistência ao Cisalhamento , Neoplasias/radioterapia , Dente , Esmalte Dentário , Dentina , Dente Serotino , Neoplasias
7.
Rev. odontol. UNESP (Online) ; 46(1): 51-55, jan.-fev. 2017. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-845609

RESUMO

Introdução: Os cimentos de ionômero de vidro possuem limitações devido à sua baixa resistência mecânica, a qual está diretamente relacionada com a proporção pó/líquido e a sua manipulação. Com o intuito de padronizar o proporcionamento e a manipulação, surgiram os cimentos de ionômero de vidro encapsulados, os quais possuem proporção pré-estabelecida e manipulação mecânica. Objetivo: Comparar, in vitro, a resistência ao desgaste entre os cimentos de ionômero de vidro pó/líquido (Riva self cure e Riva light cure) e os encapsulados (Riva self cure e Riva light cure). Material e método: As amostras foram divididas em quatro grupos, tendo sido confeccionados 48 corpos de prova (n=12), sendo 12 para cada grupo, com as seguintes dimensões: 7 mm de diâmetro e 4 mm de espessura. O desgaste foi avaliado de acordo com a massa perdida no processo de escovação (10.000 ciclos). Os valores obtidos na diferença entre a massa inicial e a massa final foram submetidos à análise de variância ANOVA e Teste de Tamhane (p<0,05). Resultado: Segundo os resultados obtidos, todas as amostras sofreram perda de massa estatisticamente significativa e, em ordem crescente de desgaste, temos os cimentos de ionômero de vidro modificado por resina ‒ para os quais não houve diferença significativa entre o sistema pó/líquido (ΔM=11,62 mg e p=0,001) e o encapsulado (ΔM=12,96 mg e p=0,003) (p>0,05) ‒ seguidos pelo convencional pó/líquido (ΔM=20,68 mg e p=0,014) e o convencional encapsulado (ΔM=47,95 mg e p=0,002). Conclusão: Pode-se conseguir uma resistência ao desgaste semelhante e até melhor no sistema pó/líquido.


Introduction: The glass ionomer cements presents limitations because of their low mechanical strength, which is directly related to the powder / liquid proportion and handling. Aiming to standardize the proportioning and handling, first came the encapsulated glass ionomer cements, which have pre-determined ratio and mechanical manipulation. Objective: To compare the in vitro wear resistance of the encapsulated glass ionomer cements (Riva Self Cure and Riva Light Cure) and powder/liquid (Riva Self Cure and Riva Light Cure). Material and method: The samples were divided into four groups which were made 48 specimens (n=12), 12 for each group with 7 mm diameter by 4 mm thick, and the wear was evaluated according to the mass lost in the process of brushing (10,000 cycles). The obtained values on the difference of the initial and final mass were analyzed using ANOVA and Tamhane's test (p<0.05). Result: Resulting found that all groups had loss of statistically significant mass, and in ascending order of wear have the light-cured glass, which there was no statistically significant differences between the powder /liquid ionomer (ΔM=11,62mg p=0.001) and encapsulated (ΔM=12,96mg p=0.003) (p<0,05), followed by conventional self-curing (ΔM=20,68mg p=0.014) and encapsulated self-curing (ΔM=47,95mg p=0.002). Conclusion: Conclude that despite the glass ionomer cement encapsulated standardize the proportion and handling, you can get a similar resistance to wear and even better in powder /liquid.


Assuntos
Técnicas In Vitro , Análise de Variância , Desgaste dos Dentes , Cimentos de Ionômeros de Vidro
8.
Dental Press J Orthod ; 22(6): 61-67, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29364381

RESUMO

OBJECTIVE: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. METHODS: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. RESULTS: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. CONCLUSIONS: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.


Assuntos
Ligas Dentárias/química , Análise do Estresse Dentário , Desenho de Aparelho Ortodôntico , Fechamento de Espaço Ortodôntico/instrumentação , Fios Ortodônticos , Titânio/química , Fenômenos Biomecânicos , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas , Estresse Mecânico , Fatores de Tempo
9.
RFO UPF ; 21(2): 191-195, 30/08/2016.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-837212

RESUMO

Objetivo: comparar a resistência à compressão entre os cimentos de ionômero de vidro (CIVs) encapsulados (Riva self cure®e Riva light cure ®) e os seus correspondentes do sistema pó/líquido (Riva self cure® e Riva light cure®). Materiais e método: para o teste de resistência à compressão, doze corpos de prova foram confeccionados para cada grupo, em matrizes de aço inoxidável com 4,0 mm ± 0,1 mm de diâmetro e 6,0 mm ± 0,1 mm de altura. Os testes foram conduzidos em máquina de ensaios universal Shimadzu®, com velocidade de deslocamento de 1,0 mm/min. Após análise, os dados foram submetidos aos testes estatísticos ANOVA 2 fatores e pós-teste Tamhane. Resultados: houve diferença estatisticamente significativa (p < 0,05) apenas entre os CIVs encapsulados. As médias de resistência à compressão em valores absolutos são de 126,07 MPa para o CIV encapsulado fotopolimerizável, 118,34 MPa para o pó/líquido fotopolimerizável, 95,87 MPa para o encapsulado autopolimerizável e 122,07 MPa para o pó/líquido autopolimerizável. Conclusão: os CIVs encapsulados não apresentam valores superiores de resistência à compressão quando comparados ao sistema pó/líquido.

10.
RFO UPF ; 21(2): 219-223, 30/08/2016.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-837220

RESUMO

Introdução: uma polimerização adequada é crucial para a obtenção das propriedades físicas ideais e o desempenho clínico das resinas compostas. Objetivo: avaliar o grau de conversão (GC) e dureza de resinas compostas fotoativadas com diferentes potências e tempos de polimerização. Materiais e método: foram confeccionados oitenta (n = 80) corpos de prova de re-sina composta (FiltekTM Z350 XT na cor A2B) com 4 mm de diâmetro e 2 mm de espessura, desses, quarenta (n = 40) foram destinados à avaliação do grau de conversão e quarenta (n = 40) para dureza. Foram feitos dez (n = 10) corpos de prova para cada grupo avaliado, sendo cinco para avaliar o grau de conversão e cinco, a dureza (P10T2, P7T2, P4T2, P1T2, P10T4, P7T4, P4T4, P1T4). Tendo as resinas do grau de conversão e de dureza fotoativadas por LEDS em 20 segundos na intensidade de potência de 1.000 mW/cm2, 700 mW/cm2, 400 mW/cm2 e 100 mW/cm2, os grupos P10T2, P7T2, P4T2 e P1T2, respectivamente. Os grupos P10T4, P7T4, P4T4 e P1T4 foram polimerizados na mesma intensidade de potência de luz, no entanto, com tempo de 40 segundos. Resultado: em relação ao grau de conversão, as resinas do P1T2 tiveram o menor valor, alcançado em média 22,67%, e o P10T4, com média 87,09%, alcançou o maior valor. Em relação à dureza, as resinas do P1T2 tiveram também a pior média, com 30,93 Kgf/mm², e o P10T4, a melhor média, com 82,02 Kgf/mm². Conclusão: quanto maior a potência do aparelho foto-polimerizador, maior será o GC e a dureza das resinas compostas. Os resultados deste estudo sugerem que um aparelho com intensidade de 100 mW/cm² não oferece um grau de conversão e dureza satisfatório, comprometendo o desempenho do material restaurador.

11.
RSBO (Impr.) ; 10(4): 170-177, Oct.-Dec. 2013. tab
Artigo em Inglês | LILACS | ID: lil-766090

RESUMO

Introduction: The finite element method (FEM) involves a series of computational procedures to calculate the stress in each element, which performs a model solution. Such a structural analysis allows the determination of stress resulting from external force, pressure, thermal change, and other factors. This method is extremely useful for indicating mechanical aspects of biomaterials and human tissues that can hardly be measured in vivo. The results obtained can then be studied using visualization software within the FEM environment to view a variety of parameters, and to fully identify implications of the analysis. Objective: An overview to show application of FEM in dentistry was undertaken. Literature review: This paper shows the basic concept, advances, advantages, limitations and applications of finite element method (FEM) in dentistry. Conclusion: It is extremely important to verify what the purpose of the study is in order to correctly apply FEM.

12.
Eur J Dent ; 7(1): 86-93, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23407620

RESUMO

OBJECTIVE: The aim of this study was to evaluate the degree of conversion and hardness of different composite resins, photo-activated for 40 s with two different light guide tips, fiber optic and polymer. METHODS: Five specimens were made for each group evaluated. The percentage of unreacted carbon double bonds (% C═C) was determined from the ratio of absorbance intensities of aliphatic C═C (peak at 1637 cm(-1)) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements were performed in a universal testing machine. A 50 gf load was used and the indenter with a dwell time of 30 seconds. The degree of conversion and hardness mean values were analyzed separately by ANOVA and Tukey's test, with a significance level set at 5%. RESULTS: The mean values of degree of conversion for the polymer and fiber optic light guide tip were statistically different (P<.001). The hardness mean values were statistically different among the light guide tips (P<.001), but also there was difference between top and bottom surfaces (P<.001). CONCLUSIONS: The results showed that the resins photo-activated with the fiber optic light guide tip promoted higher values for degree of conversion and hardness.

13.
Microsc Res Tech ; 75(12): 1639-45, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22851485

RESUMO

The aim of this study was to evaluate the shear bond strength of repairs in porcelain conditioned with laser. Sixty porcelain discs were made and six groups were formed (n = 10): G1: conditioning with laser with potency 760 mW; G2: conditioning with laser with potency 760 mW and application of 37% phosphoric acid for 15 s; G3: conditioning with laser with potency 900 mW; G4: conditioning with laser with potency 900 mW and application of 37% phosphoric acid for 15 s; G5: application of 37% phosphoric acid for 15 s (group control) and G6: application of 10% hydrofluoric acid for 2 min. The composite resin was insert of incremental layers at the porcelain surface aided with a metal matrix, and photoactivation for 20 s each increment. The specimens were submitted to a thermal cycling by 1000 cycles of 30 s in each bath with temperature between 5 and 55°C. After the thermal cycling, specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance and Tukey's tests with 5% significance. The averages and standard deviation founded were: G1, 11.25 (±3.10); G2, 12.32 (±2.65); G3, 14.02 (±2.38); G4, 13.44 (±2,07); G5, 9.91 (±2,18); G6, 12.74 (±2.67). The results showed that the femtosecond laser produced a shear bond strength of repairs in porcelain equal to the hydrofluoric acid and significantly superior to the use of phosphoric acid.

14.
Am J Orthod Dentofacial Orthop ; 140(2): e53-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21803234

RESUMO

INTRODUCTION: The objective of this research was to compare the effect of preactivation on the force system of beta-titanium T-loop springs (TLSs). METHODS: Twenty TLSs with dimensions of 6 × 10 mm, of 0.017 × 0.025-in beta-titanium alloy, were randomly divided into 2 groups according to their preactivation. By using a moment transducer coupled to a digital extensometer indicator adapted to a testing machine, the amounts of horizontal force and moment produced were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation in an interbracket distance of 23 mm. The moment-to-force ratio, the "neutral position" and the load-deflection ratio were also calculated. RESULTS: TLSs preactivated by curvature delivered horizontal forces significantly lower than those preactivated by concentrated bends. No differences were found in relation to the moments produced throughout the deactivation of both groups. The moment-to-force ratios were systematically higher on the TLSs preactivated by curvature than those preactivated by concentrated bends, except on 5 mm of activation. Significant differences were found in the load-deflection rates and "neutral position." CONCLUSIONS: The TLSs preactivated by curvature delivered lower horizontal forces and higher moment-to-force and load-deflection ratios than did those preactivated by concentrated bends.


Assuntos
Análise do Estresse Dentário , Desenho de Aparelho Ortodôntico , Fechamento de Espaço Ortodôntico/instrumentação , Fios Ortodônticos , Ligas Dentárias , Teste de Materiais , Distribuição Aleatória , Estresse Mecânico , Titânio
15.
Am J Orthod Dentofacial Orthop ; 140(2): e85-92, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21803238

RESUMO

INTRODUCTION: This study evaluates the changes in the force system of the beta-titanium T-loop spring (TLS) caused by stress relaxation. METHODS: Ninety TLSs with dimensions of 6 × 10 mm, made of 0.017 × 0.025-in beta-titanium alloy and preactivated by concentrated bends, were randomly distributed into 9 groups according to the time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief by trial activation. The other 8 groups were tested after 24, 48, and 72 hours, and 1, 2, 4, 8, and 12 weeks. By using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amounts of horizontal forces and moments and the moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation in an interbracket distance of 23 mm. RESULTS: The horizontal forces and moments were higher (P <0.001) for group 1 compared with the other 8 groups, which were not different among themselves. All groups produced similar moment-to-force ratios (P = 0.600), with no influence of time. CONCLUSIONS: The TLSs preactivated by concentrated bends had progressive load decreases over time, and this effect is critical in the first 24 hours.


Assuntos
Análise do Estresse Dentário , Fios Ortodônticos , Estresse Mecânico , Análise de Variância , Ligas Dentárias , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas , Fatores de Tempo , Titânio
16.
Oral Health Prev Dent ; 9(4): 369-74, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22238735

RESUMO

PURPOSE: To assess the current situation of white enamel lesions on vestibular surfaces of permanent maxillary incisors, diagnosed 6 years ago, without clinical intervention. MATERIALS AND METHODS: The prospective study reassessed 53 students of both sexes, aged between 13 and 18 years old, all attending the public school system in Natal, Brazil. Data collection was performed by calibrated examiners, and a clinical chart consisting of demographic data on dental caries, oral hygiene and gingival condition was prepared. A tactile-visual examination was conducted using a clinical mirror and periodontal probe. Data compilation and analysis were carried out using SPSS software. In this analysis, the chi-square test was used for qualitative independent variables. To identify the net effect of treatment, multiple logistic analysis with forward stepwise model selection was performed. RESULTS: The final sample was composed of 106 lesions in the 53 individuals, with mean age of 15.02 years, visible plaque index (VPI) of 23.34%, and gingival blood indices (GBI) of 25.92%. A statistically significant relationship (P = 0.003) was found between initial DMFS and the prognosis of white enamel lesions. CONCLUSION: It was observed that past caries experience and dental plaque were the main predictive factors for negative lesion outcomes, demonstrating the need for oral hygiene control through continuing preventive measures.


Assuntos
Cárie Dentária/patologia , Esmalte Dentário/patologia , Adolescente , Brasil , Distribuição de Qui-Quadrado , Estudos de Coortes , Estudos Transversais , Índice CPO , Índice de Placa Dentária , Progressão da Doença , Feminino , Humanos , Incisivo/patologia , Modelos Logísticos , Masculino , Maxila , Índice de Higiene Oral , Prognóstico , Estudos Prospectivos
17.
Clín. int. j. braz. dent ; 6(1): 34-41, jan.-mar. 2010. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-716596

RESUMO

A busca crescente de pacientes por estética e opções restauradoras ametálicas tem conduzido à procura por alternativas para a reconstrução dentária, por meio de restaurações que simulem as características de um dente natural. Dentre os materiais restauradores odontológicos, as cerâmicas se destacam, tanto do ponto de vista estético-funcional como em relação à durabilidade e resistência. Atualmente, existe no mercado ampla variedade de sistemas totalmente cerâmicos, dentre os quais aparece o sistema In-Ceram, com suas variações In-Ceram Alumina, In-Ceram Spinell e In-Ceram Zircônia, que ainda necessitam de ser investigados minuciosamente. Assim, este artigo apresenta um caso clínico que demonstra a confecção de uma coroa sem metal para um elemento canino superior direito. Foi utilizado como material para infra-estrutura o sistema In-Ceram Alumina e a porcelana convencional Vitadur Alpha para revestimento, o que acarretou estética satisfatória, que mimetiza aspectos de um dente natural.


The increasing search patients for esthetic restorative options lead to the search for alternatives fot the dental reconstruction which simulate the features of a natural tooth. Between the restorative dental materials, the dental ceramics present extraordinary durability and resistance. Currently, there are a large variety of total ceramics systems in the dental market, i.e. In-Ceram system (Alumina, Spinell and Zirconia). This article has the objective to present a clinical case demonstrating the restoration of a right canine with a metal free crown using In-Ceram Alumina as the infrastructure and the conventional porcelain Vitadur Alpha as a veneering material. However, these all-ceramic systems should be submitted to longitudinal clinical evaluations, to be considered more reliable and safe, provided that the correct indications of each variation of the In-Ceramic ceramic system is respected.


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Materiais Dentários , Restauração Dentária Permanente , Estética Dentária , Ciência dos Materiais
18.
Rev. odontol. UNESP (Online) ; 39(1): 41-47, jan.-fev. 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874769

RESUMO

A proposta deste estudo foi avaliar a alteração dimensional de modelos de gesso obtidos a partir de moldes de alginato tradicional e alginatos suplementados com antimicrobiano. Foram utilizados um alginato sem desinfetante (Jeltrate tipo II) e outro suplementado com clorexidina (Avagel tipo II), que passaram pelos mesmos regimes de tratamento: sem desinfecção, imersão e spray. A solução usada foi o hipoclorito de sódio a 1% por 10 minutos. Foi utilizada para obtenção dos moldes uma moldeira perfurada confeccionada a partir de um modelo metálico padrão. Após a moldagem, os moldes foram lavados em água corrente por trinta segundos para simular remoção de saliva. Em seguida, com exceção do grupo controle, os moldes foram submetidos ao tratamento de desinfecção. Após 10 minutos, foram novamente lavados. Obtiveram-se sessenta corpos-de-prova vazados com gesso especial tipo V (Durone), que foram medidos três vezes em um Estereomicroscópio (SZX12, Olympus) para registro da média de alteração dimensional. O tratamento de desinfecção não provocou alteração significativa nos modelos obtidos de ambos os alginatos testados (tradicional p = 0,7102; com clorexidina p = 0,5832). Os resultados exibiram uma vantagem adicional e estatisticamente significante do alginato tradicional em relação ao alginato com clorexidina, no que diz respeito à alteração dimensional (p < 0,05).


The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).


Assuntos
Hipoclorito de Sódio , Desinfetantes de Equipamento Odontológico , Alginatos , Clorexidina , Desinfecção , Materiais para Moldagem Odontológica , Sulfato de Cálcio , Análise de Variância , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...